SPD for Wind Power

Fill the Contact Form and Get Reply in 2 Hours

Wind energy is one of the most mature and scalable renewable clean energy sources available today. Inside wind turbine generators, there are numerous sensitive electronic components, which are very expensive. It’s common to see wind turbine blades damaged or even bent or broken due to lightning strikes every year.

Due to the random nature of lightning, it cannot be avoided. Therefore, installing surge protection devices (SPDs) on the power lines inside the turbine is an essential lightning protection measure. It can quickly dissipate lightning currents to the ground when the wind turbine is struck by lightning, reliably reducing overvoltages to the withstand voltage value of the protected equipment.

Wind power surge protectors are suitable for:

Inverters, wind turbine electronic side, wind turbine rotor side.

Suitable for IT, TNC systems.

Technical Parameters  
Based on IEC61643-1/11 GB/T18802.11 standards II Class
Rated Voltage Un 400/690Vac
Maximum Continuous Operating Voltage Uc 760Vac
Nominal Discharge Current In(8/20μs) 15kA
Maximum Discharge Current Imax(8/20μs) 25kA
Technical MOV
Voltage Protection Level Up 3.0kV
Voltage Protection Level @5kA Up 2.5kV
Response Time ≤25ns
Maximum Backup Fuse ≤100Agl/gG
Short Circuit Withstand Capacity Isc 25kArms
Temporary Overvoltage (TOV)UT 950V/5s
TOV characteristics Tolerance
Working Conditions  
Operating Temperature -40℃…+85℃
Relative Humidity ≤95%(max40℃)
Altitude ≤4km
Protection Level IP20
Enclosure Material Thermoplastic material UL94V-0